Chapter IX. FCoE Full Offload Initiator
Copyright ©2013.Chelsio Communications. All Rights Reserved. Page 149
v. Save the Configuration
switch#copy running-config startup-config
4.2. FCoE fabric discovery verification
The verification is done 
4.2.1. Verifying the DCBX parameters
To verify the current DCBX information being exchanged, execute the below commands using
cxgbtool.
i. First step is to find the adapter number. Find it using the following command
[root@host]# cxgbtool stor s
ii. Now execute the following command to check the DCBX information.
[root@host]# cxgbtool stor a <adapter_no> --dcb-params